Analizador automático de inmunología por quimioluminiscencia. Permite analizar simultáneamente hasta 144 muestras empleando 15 reactivos distintos, con una velocidad de proceso de 120 análisis por hora. El sistema controla la gestión de reactivos en todo momento
Description
Principle of Luminescence
• Non-enzyme involved flash chemiluminescence, long stability of reagents
• ABEI label, stable in acid and alkaline solution
Main Features
• Throughput: up to 120 tests/hour
• 24 hours ready to use
• Time to first result:17 minutes
Description
Principle of Luminescence
• Non-enzyme involved flash chemiluminescence, long stability of reagents
• ABEI label, stable in acid and alkaline solution
Main Features
• Throughput: up to 120 tests/hour
• 24 hours ready to use
• Time to first result:17 minutes

Modes of Operation
• Random, Batch and STAT
Sample Loading
• Up to 144 primary tubes
• Continuous loading, STAT available
• Analyzer auto numbered
• LIS connection
Reagent Loading
• 15 reagents on board
• Continuous loading
• RFID read all info of reagent
• Refrigerated reagent area
• Random, Batch and STAT
Sample Loading
• Up to 144 primary tubes
• Continuous loading, STAT available
• Analyzer auto numbered
• LIS connection
Reagent Loading
• 15 reagents on board
• Continuous loading
• RFID read all info of reagent
• Refrigerated reagent area
Reagent Features
• Integrated kit, ready-to-use, no pretreatment required
• Integrated kit including calibrators
• Use superparamagnetic microbeads
• RFID tag storing all info of reagent
• RFID tag with built-in master curve
• 2-point calibration to adjust master curve
• Calibration stability: max 4 weeks
• Integrated kit, ready-to-use, no pretreatment required
• Integrated kit including calibrators
• Use superparamagnetic microbeads
• RFID tag storing all info of reagent
• RFID tag with built-in master curve
• 2-point calibration to adjust master curve
• Calibration stability: max 4 weeks
Other Features
• Clot detection
• Liquid level detection for reagent
• Optional ratio for sample dilution
• Auto dilution for high concentration sample
• Constant 37℃ incubation
• 15-30℃ Operating temperature
Interconnection
• Connection to LIS via COM or network
• Direct operation on LIS system to test
Dimensions Weight
• 135×64×87cm, 148kg
información adicional en www.snibe.com
• Clot detection
• Liquid level detection for reagent
• Optional ratio for sample dilution
• Auto dilution for high concentration sample
• Constant 37℃ incubation
• 15-30℃ Operating temperature
Interconnection
• Connection to LIS via COM or network
• Direct operation on LIS system to test
Dimensions Weight
• 135×64×87cm, 148kg
información adicional en www.snibe.com